Dry Cabinets for Battery Components and Materials
Controlled low-humidity storage for selected moisture-sensitive battery components, electrode materials, separators, electronic assemblies and R&D samples.
McDry helps reduce exposure to uncontrolled ambient humidity during material receiving, intermediate storage, development, testing and production.
Helps reduce moisture uptake during storage and handling.
Enclosed storage for components, packages and R&D samples.
Supports more repeatable storage conditions between processes.
Moisture can influence sensitive battery materials and components
Battery development and manufacturing involve materials and components with different moisture sensitivities. Depending on the chemistry, packaging and process, uncontrolled humidity can affect material handling, surface condition and downstream process consistency.
McDry provides an enclosed low-humidity environment for suitable materials during intermediate storage, research, quality control and selected production activities.
Support approved materials during dry-room downtime
In battery manufacturing, a dry room may occasionally be unavailable due to maintenance, technical problems or production interruptions.
McDry can provide temporary enclosed low-humidity storage for approved battery materials and components while a dry room is unavailable. It is not, by itself, a power-outage backup system.
During planned dry-room maintenance, the cabinet must remain connected to a power source independent of the dry room. For a power outage, it must be used with an appropriately specified UPS or other emergency power supply.
Dry-room maintenance
Temporary low-humidity storage for approved materials while the dry room is being serviced, provided the cabinet remains powered from an independent electrical supply.
Power-outage contingency
Use only with an appropriately sized UPS or other emergency power supply to maintain active humidity control.
Temporary production stoppage
Suitable materials and components can remain in a controlled dry-storage environment while the cabinet remains powered and within its specified operating conditions.
Defined operating conditions
Required humidity or dew point, storage duration, cabinet load, door-opening frequency and recovery time must be verified.
What uncontrolled humidity can influence
The actual effect depends on the battery chemistry, material condition, storage duration, packaging and manufacturing process.
Moisture uptake
Selected electrode materials, separators, polymers and hygroscopic components can absorb moisture from ambient air.
Surface changes
Humidity can contribute to oxidation, corrosion or changes in the surface condition of selected metallic and electronic parts.
Process variation
Different storage conditions can lead to variation between development trials, quality checks and production batches.
Handling inconsistency
Uncontrolled storage may influence powder handling, component cleanliness and material traceability.
Materials and components that may benefit from dry storage
Suitability must be reviewed individually. These examples do not mean that every material, cell or battery configuration can be stored safely in a standard McDry cabinet.
Electrode materials
Selected dry materials used in electrode development, preparation and evaluation.
- Selected active-material samples
- Dry coated-electrode samples
- Current collectors
- Development and reference samples
Separators, films and seals
Selected films, membranes, gaskets and sealing components requiring protection from uncontrolled humidity.
- Separator films
- Porous membranes
- Insulation materials
- Selected seals and gaskets
Electrical and mechanical components
Components used in battery packs, modules and battery management systems.
- Tabs and busbars
- Connectors and terminals
- Sensors and electronic assemblies
- Battery-management-system components
R&D samples and approved assemblies
Selected samples, components and assemblies used during development, testing and process evaluation.
- Pilot-line samples
- Reference components
- Selected cells or modules after safety review
- Quality-control samples
Typical materials, risks and review requirements
| Application | Moisture-related concern | How McDry may support storage | Important review point |
|---|---|---|---|
| Dry electrode materials | Moisture uptake, altered handling and variation between development or production batches | Enclosed low-humidity storage between receiving, preparation and use | Chemistry, material form, SDS and required dew point must be confirmed |
| Coated electrodes and separators | Moisture exposure, surface changes and inconsistent intermediate-storage conditions | Helps reduce exposure to uncontrolled ambient humidity | Solvent-wet or reactive materials require separate safety review |
| Pack and module components | Oxidation, corrosion and surface contamination of selected metallic or electronic parts | Organised dry storage for suitable parts and assemblies | Energised, damaged or thermally unstable assemblies may require dedicated safety storage |
| R&D and quality samples | Different storage conditions between tests and evaluation activities | Helps maintain repeatable conditions for approved samples | Chemistry, state of charge, condition and packaging must be documented |
| Temporary storage during dry-room downtime | Unexpected increase in ambient humidity during dry-room maintenance, shutdown or temporary process interruption | Provides an enclosed low-humidity environment for approved materials while surrounding room conditions temporarily change, provided continuous power is maintained | An independent power source is required for planned maintenance; a correctly sized UPS or emergency supply is required for outages. Humidity or dew point, hold time, recovery and material safety must be confirmed |
Evaluate the material before placing it in a McDry cabinet
Identify the material
Confirm chemistry, physical form, condition, packaging and safety classification.
Review requirements
Check the SDS, supplier instructions and required humidity or dew point.
Select the cabinet
Consider quantity, package size, target humidity and door-opening frequency.
Control access
Label materials clearly and return approved items promptly after use.
Controlled low-humidity storage without continuous nitrogen consumption
McDry uses a zeolite-based drying unit to maintain a controlled dry environment. Depending on the selected model and operating conditions, storage down to 1% RH is available.
Standard operation does not require a continuous nitrogen supply.
Ultra-low-humidity storage
Selected configurations provide storage down to 1% RH.
No continuous nitrogen supply
Standard operation uses an electric zeolite-based dry unit.
Conditional dry-room downtime support
Provides an additional enclosed dry-storage environment for approved materials during temporary dry-room downtime when continuous power and specified operating conditions are maintained.
Organised intermediate storage
Structured storage of approved materials and samples.
European technical support
Product selection, service and spare-parts support.
Two-year SSG warranty
Cabinets supplied by SSG are generally covered for two years from the SSG shipment date.
Select the McDry series according to capacity and access frequency
Compact laboratory storage
Suitable for smaller quantities of approved samples, components and R&D materials.
- Space-saving cabinet sizes
- Research and laboratory use
- Small-volume storage
General-purpose storage
Suitable for regular intermediate storage with moderate cabinet-access frequency.
- Large storage capacity
- Cost-effective configuration
- Production and laboratory use
Frequent-access storage
Suitable for larger quantities and workflows requiring more frequent access.
- Rapid humidity recovery
- Large-volume storage
- Production environments
McDry is not a fire-rated or explosion-proof battery storage cabinet
A standard McDry cabinet must not automatically be used for charged, damaged, swollen, leaking, thermally unstable or recalled cells and batteries.
Electrolytes, solvent-wet electrodes, volatile liquids, flammable materials and other hazardous substances must not be stored without prior technical and safety review.
Please provide the relevant Safety Data Sheet, battery chemistry, state of charge, condition, quantity and packaging information.
McDry for battery components and selected materials
Review typical applications, moisture-related risks, model selection and important safety considerations.
Dry storage for battery components and materials
Can lithium-ion batteries be stored in a McDry cabinet?
Not automatically. McDry may be suitable for selected battery components and approved samples, but it is not a fire-rated or explosion-proof battery safety cabinet.
Can McDry replace a battery dry room or glovebox?
No. Some battery processes require an extremely low dew point, controlled atmosphere or glovebox.
Can McDry support storage during dry-room downtime?
Yes, conditionally. During planned dry-room maintenance, McDry can provide temporary low-humidity storage for approved materials when connected to a power source independent of the dry room. During a power outage, it must be paired with an appropriately specified UPS or other emergency power supply. McDry alone should not be described as a power-outage backup system. The required humidity or dew point, hold time, door-opening frequency and recovery performance must be validated for the selected cabinet and application.
Can McDry be used in sub-zero ambient temperatures?
Standard McDry models should not be assumed suitable for sub-zero ambient temperatures. The permitted operating conditions must be confirmed for the selected model before use.
Can electrolyte or solvent-wet materials be stored in McDry?
Electrolytes, solvent-wet electrodes and volatile or flammable materials must not be stored without prior technical and safety review.
Does McDry require continuous nitrogen?
Standard McDry operation does not require a continuous nitrogen supply.
Which McDry series is suitable for battery R&D?
MCU may suit smaller laboratory quantities. MC and DXU may be more appropriate for larger storage volumes or frequent access.
What information is required for application review?
Please provide the battery chemistry, material name, SDS, state of charge, condition, packaging, quantity, target humidity, required dew point and access frequency.
Learn more about McDry ultra-low-humidity dry cabinets
Explore the complete McDry DXU, MC and MCU series, technical information and application guidance for moisture-sensitive components and materials.
Visit the McDry Specialist Website →
Discuss your battery-component storage requirements with SSG
Tell us what you need to store, the battery chemistry, package format, required humidity or dew point, quantity and access frequency.