MCDRY APPLICATION SOLUTION

Dry Cabinets for AI Hardware, Semiconductor Components & Data Center Electronics

Ultra-low humidity dry storage for GPU-related semiconductor packages, AI accelerators, IC packages, high-density PCBs, memory devices, optical transceivers and other moisture-sensitive electronics used in AI hardware and data center systems.

McDry provides controlled low-humidity storage for suitable moisture-sensitive electronic components during manufacturing, assembly, intermediate storage, service and long-term preservation.

Down to approx. 1% RH No continuous nitrogen supply GPU & semiconductor component storage European support
Semiconductor component storage Controlled dry storage for suitable IC packages, GPU-related components, memory devices and electronic assemblies.
Ultra-low humidity Selected McDry models support controlled storage down to approximately 1% RH.
AI hardware supply chain Suitable for component manufacturing, assembly, intermediate storage, service stock and long-term preservation.
DRY CABINET FOR AI HARDWARE

Dry storage for the semiconductor components behind AI systems

AI servers and high-performance computing systems depend on advanced semiconductor components including GPU-related packages, AI accelerators, memory devices, IC packages, high-density PCBs, power electronics and optical transceivers.

Suitable moisture-sensitive components may require controlled low-humidity storage during manufacturing, assembly, intermediate storage, repair and long-term preservation.

MOISTURE-RELATED RISKS

Why dry storage matters for AI and semiconductor components

Moisture exposure can affect semiconductor packages, PCB assemblies and long-term storage stability depending on component design, packaging, handling conditions and process requirements.

01

Moisture absorption

Moisture-sensitive semiconductor packages can absorb moisture from ambient air during storage and handling.

02

Process reliability

Controlled dry storage can help maintain more consistent component conditions before assembly, soldering and integration.

03

Long-term preservation

Ultra-low humidity storage can help reduce additional moisture exposure during extended component storage.

04

High-value electronics

GPU-related packages, AI accelerators and advanced semiconductor devices can represent high-value inventory that requires reliable storage conditions.

DRY CABINET FOR AI & DATA CENTER ELECTRONICS

What AI hardware and semiconductor components can be stored in a dry cabinet?

Typical applications include GPU-related components, AI accelerators, semiconductor packages, memory devices, PCBs, optical transceivers and selected electronic service parts. Final suitability depends on the actual component and storage requirement.

GPU components & AI accelerators

Dry storage for suitable GPU-related semiconductor packages and accelerator components used in high-performance AI systems.

  • GPU-related semiconductor packages
  • AI accelerator components
  • Advanced processor packages
  • Prototype AI computing hardware

Semiconductor components, IC packages & memory

Controlled dry storage for selected semiconductor packages and memory components before production, assembly or long-term storage.

  • IC packages
  • Memory devices
  • Moisture-sensitive semiconductor components
  • Packaged electronic devices

High-density PCBs

Bare and assembled printed circuit boards used in AI servers, computing platforms and supporting electronics.

  • Bare PCBs
  • Assembled PCBs
  • AI server circuit boards
  • Prototype and development boards

Optical transceivers & network electronics

Selected optical transceivers, communication modules and sensitive electronic components used for high-speed data transfer in AI and data center infrastructure.

  • Optical transceivers
  • Optical modules
  • Network electronics
  • High-speed communication modules

Power semiconductor & power electronics

Selected power semiconductor devices and electronic modules used in AI computing and server power systems.

  • Power semiconductor components
  • Power control electronics
  • Server power assemblies
  • Selected electronic modules

Service parts & spare electronics

Moisture-sensitive replacement boards, modules and spare semiconductor components stored for maintenance and long-term support.

  • Replacement PCBs
  • Spare semiconductor components
  • Electronic modules
  • Long-term service stock
DRY STORAGE FOR SEMICONDUCTOR COMPONENTS

Why use an ultra-low humidity dry cabinet for AI hardware?

Modern AI hardware combines high-value semiconductor packages, GPU-related components, high-density PCB assemblies, memory devices and high-speed optical communication electronics.

MANUFACTURING & ASSEMBLY

Keep moisture-sensitive semiconductor components dry before assembly

During manufacturing, GPU-related packages, AI accelerators, IC packages and other suitable moisture-sensitive components may be exposed to ambient humidity between receiving, production steps and final assembly.

McDry provides a controlled low-humidity environment for components that require protection from additional moisture exposure.

Application review: Required humidity depends on the specific component, packaging, handling process and manufacturer requirements.
SERVICE & LONG-TERM STORAGE

Protect high-value AI electronics during long-term storage

Spare PCBs, semiconductor devices, optical transceivers and electronic modules may remain in storage for extended periods before repair, maintenance or replacement use.

Controlled dry storage can help maintain stable environmental conditions for suitable components during intermediate and long-term preservation.

Important: McDry does not replace component-manufacturer handling, baking or floor-life instructions where such procedures apply.
APPLICATION OVERVIEW

AI hardware components, moisture risks and dry storage needs

Component group Typical storage concern How dry storage can help Important review point
GPU & AI accelerator packages Moisture absorption during manufacturing, handling and intermediate storage Provides stable low-humidity storage for suitable moisture-sensitive semiconductor devices Follow component-manufacturer handling, MSL and process requirements
IC packages & memory devices Ambient moisture exposure before production, assembly or long-term storage Helps reduce additional moisture uptake during controlled storage Package type, MSL and manufacturer instructions should be confirmed
High-density PCBs Variable environmental exposure before assembly, rework or long-term storage Supports controlled conditions between production processes Board condition, assembly status and process requirements should be reviewed
Optical transceivers & network components Sensitive electronics may require protection from uncontrolled humidity exposure Provides enclosed low-humidity storage for suitable components Optical component type, packaging and manufacturer requirements
Service & spare electronics Extended storage periods before maintenance, repair or replacement Supports stable long-term dry storage for suitable spare components Required humidity and packaging should be confirmed for each component type
ELECTRONICS STORAGE WORKFLOW

Use controlled dry storage throughout the component lifecycle

1

Receiving

Review packaging, component type, storage requirements and moisture sensitivity.

2

Controlled dry storage

Store suitable moisture-sensitive components under the required low-humidity conditions.

3

Assembly or integration

Remove only the quantity required for production, testing, assembly or system integration.

4

Return or preservation

Return remaining suitable components promptly or maintain controlled storage for long-term use.

WHY MCDRY

Ultra-low humidity storage for high-value electronics

McDry uses a zeolite-based drying unit to maintain a controlled dry environment for suitable moisture-sensitive components and materials.

Depending on the selected model and operating conditions, storage down to approximately 1% RH is available. Standard humidity control does not require a continuous nitrogen supply.

Stable ultra-low humidity

Selected McDry models provide controlled storage down to approximately 1% RH.

No continuous nitrogen supply

Standard humidity control uses an electric zeolite-based drying unit.

Designed for long-term storage

Suitable for controlled storage of valuable electronic components over extended periods.

Fast humidity recovery with DXU

DXU configurations are suited to production environments where cabinet doors are opened more frequently.

European support & two-year warranty

SSG provides model selection, quotations, service and spare-parts support. Cabinets supplied by SSG are generally covered for two years from the SSG shipment date.

CABINET SELECTION

Which McDry is suitable for your AI hardware storage?

Model selection depends on storage volume, target humidity, component dimensions, access frequency and available installation space.

MCU

Compact R&D storage

Suitable for laboratories, AI hardware development and smaller quantities of semiconductor or PCB components.

  • Compact footprint
  • R&D and prototype environments
  • Small-volume semiconductor storage
  • Laboratory use
DXU

Frequent-access production storage

Suitable for production environments where semiconductor components or PCBs are accessed frequently.

  • Fast humidity recovery
  • Frequent door opening
  • Production environments
  • Large-volume electronics storage

Final model selection depends on target humidity, component quantity, package dimensions, access frequency, available installation space and production requirements.

Typical users: semiconductor manufacturers, electronics manufacturers, AI hardware developers, data center equipment suppliers, R&D laboratories, service centers and system integrators.

APPLICATION REVIEW

Storage requirements should be confirmed for the actual component

McDry suitability depends on component type, moisture sensitivity, packaging, target humidity, storage quantity, handling method and production process.

Component-manufacturer requirements, MSL controls, baking instructions and other process specifications should continue to be followed where applicable.

FREQUENTLY ASKED QUESTIONS

Dry cabinets for AI hardware, GPUs and semiconductor components

What is a dry cabinet for AI hardware?

A dry cabinet for AI hardware provides controlled low-humidity storage for suitable moisture-sensitive semiconductor components, GPU-related packages, IC packages, PCBs, memory devices and other electronic parts used in AI computing systems.

Can McDry be used as a dry cabinet for semiconductor components?

Yes, McDry can be used for suitable moisture-sensitive semiconductor components such as IC packages, memory devices and other packaged electronic devices. The required humidity depends on component type, packaging and process requirements.

Can McDry store GPU components and AI accelerators?

McDry may be suitable for compatible GPU-related semiconductor packages, AI accelerator components and other moisture-sensitive electronic devices. Required humidity and handling conditions should be reviewed for the actual component.

Can optical transceivers be stored in a dry cabinet?

Suitable moisture-sensitive optical transceivers, optical modules and communication electronics may benefit from controlled dry storage. Storage requirements should be confirmed according to the component and manufacturer specifications.

Can McDry be used for data center electronics?

McDry may be used for suitable moisture-sensitive electronic components and spare parts used in data center equipment, such as PCBs, semiconductor devices, memory components, electronic modules and optical transceivers. It is not intended to control the environment of an operating data center room or server rack.

Is McDry suitable for high-density PCBs?

McDry can be used for suitable bare or assembled PCBs requiring controlled low-humidity storage. Required storage conditions depend on board condition, assembly status and production requirements.

Can McDry maintain approximately 1% RH?

Selected McDry models support ultra-low humidity storage conditions down to approximately 1% RH, depending on the model and operating conditions.

Does a McDry dry cabinet require nitrogen?

Standard McDry humidity control does not require a continuous nitrogen supply. The cabinet uses an electric zeolite-based drying unit.

Which McDry series is suitable for AI electronics?

MCU can be suitable for compact R&D storage, MC for larger-capacity or long-term storage, and DXU for production environments with more frequent access and faster humidity recovery.

What information is required for McDry model selection?

Please provide the component or material name, package dimensions, storage quantity, target humidity, access frequency and available installation space.

TECHNICAL APPLICATION REVIEW

Need a dry cabinet for GPU, AI or semiconductor components?

Tell us what you need to store, the component type, required humidity, package dimensions, storage quantity and expected access frequency. SSG will help evaluate the appropriate McDry configuration.

Request a McDry Recommendation