HIOKI RM2610 Electrode Resistance Measurement System

HIOKI RM2610 Electrode Resistance Measurement System

HIOKI

Electrode Resistance Measurement System RM2610

Quantitative Evaluation of Lithium-ion Battery Electrode Sheets

The HIOKI RM2610 Electrode Resistance Measurement System simultaneously calculates the composite layer volume resistivity and the interface resistance between the composite layer and the aluminum or copper current collector foil of lithium-ion battery electrode sheets.

Quantitative Electrode Sheet Evaluation

The RM2610 evaluates two key electrical properties of lithium-ion battery electrode sheets in a single measurement cycle: composite layer volume resistivity and interface resistance between the composite layer and the current collector.

By separating resistance components that are difficult to isolate using conventional resistance measurements, the system provides quantitative data for material development, production process optimization, and quality assurance before cell assembly.

Key Features

Two Resistance Parameters

Simultaneously calculate composite layer volume resistivity and interface resistance between the composite layer and the collector foil.

Results Within a Minute

Obtain quantitative electrode resistance results within one minute to support efficient evaluation during development and production.

Multi-point Probe Measurement

A probe head equipped with 46 ultra-fine probes measures the electrode surface from multiple points for reliable resistance analysis.

Contact Check

A contact check function verifies electrical contact for each probe and supports reliable measurement with configurable threshold settings.

Two Key Parameters for Electrode Evaluation

The RM2610 separates the electrical characteristics of the electrode sheet into two quantitative resistance parameters.

Composite Layer Volume Resistivity

Quantifies the electrical resistivity of the composite layer of the electrode sheet and provides data for evaluating electrode material composition and conductive characteristics.

Interface Resistance

Quantifies the resistance at the interface between the composite layer and the aluminum or copper current collector foil.

Measurement and Analysis Principle

The RM2610 combines multi-point resistance measurement with numerical analysis to separate composite layer volume resistivity and interface resistance.

01

Contact

The 46 ultra-fine probes contact the surface of the electrode sheet.

02

Measure

Current is applied between selected probes and the resulting potential distribution is measured from multiple directions.

03

Calculate

RM2612 Resistance Calculation Software uses numerical analysis to calculate the unknown resistance parameters.

04

Evaluate

Composite layer volume resistivity and interface resistance are output as quantitative electrode evaluation results.

Key Specifications

Measurement Parameters Composite layer volume resistivity and interface resistance
Measurement Time Results within 1 minute
Resistance Measurement DC 4-terminal method
Probe System 46 ultra-fine probes
Contact Check Contact check function with threshold settings
Electrode Resistance Meter HIOKI RM2611
Resistance Calculation Software HIOKI RM2612
Probe Press Unit HIOKI RM9003
Probe Head HIOKI RM9004
Connection Cable HIOKI RM9005

Typical Applications

The RM2610 supports quantitative electrode evaluation across lithium-ion battery research, process development, and quality control.

Electrode Material Development

Evaluate changes in electrode resistance caused by active materials, conductive additives, binders, and formulation conditions.

Process Optimization

Quantitatively compare electrode characteristics when optimizing mixing, coating, drying, and pressing conditions.

Quality Control

Use resistance parameters to evaluate electrode sheet consistency and support quality control before cell assembly.

How RM2610 Works

The RM2610 measures electrode sheet resistance and analyzes the results to separate composite layer resistivity from interface resistance.

Measure the Electrode Sheet

Measure the potential distribution of the electrode sheet using the multi-point probe system.

Analyze Resistance

Analyze the measured data to calculate the electrical resistance characteristics of the electrode sheet.

Separate Resistance Components

Separate composite layer resistivity from the interface resistance for quantitative electrode evaluation.

Key Benefits

The RM2610 provides quantitative resistance data that supports faster electrode development, process optimization, and quality evaluation.

Faster Evaluation

Obtain quantitative electrode resistance results within one minute to accelerate development and comparison work.

 

Clear Resistance Separation

Separate composite layer resistivity from interface resistance for more detailed electrode evaluation.

 

Better Process Insight

Compare resistance characteristics to understand the effects of materials and manufacturing conditions.

 

Reliable Quality Control

Use quantitative resistance data to evaluate electrode consistency and support quality control.

 

Related Items

Slurry Analytical System

Quantitatively evaluate lithium-ion battery slurry conductivity and dispersion using impedance analysis.

Powder Impedance Measurement System

Evaluate the electrical characteristics of battery electrode materials in powder form using impedance measurement.